Empty dust discharge valve 1 by pressing apart
lips of discharge slot as indicated by arrows.
Clean discharge slot from time to time.
Remove any caked dirt by pressing together
upper section of valve.
Undo clip fasteners 1.
Take off hood 2 and remove cartridge 3.
Clean cartridge, replace at least once a year.
Clean cartridge 3.
Using dry compressed air (max. 5 bar), blow out
from inside to outside (or in difficult cases, tap
out, taking care not to damage cartridge, or wash
according to manufacturer’s instructions).
Gaskets on filter cartridge can become damaged
through regular removal and replacement. Check
paper filter (light showing through) and gaskets
for damage.
Replace if necessary.
6.4.3 Dry Type Air Cleaner
Discharge Valve
Never clean filter cartridge with pet-
rol or hot fluids.
After five cleaner services or after two years at
latest, replace safety cartridge 4 (never clean).
To do so:
- Undo hex nut 5 and remove cartridge 4.
- Install new cartridge, fit and tighten hex nut.
Install cartridge 3, replace hood 2 and do up clip
fasteners 1.
Filter Cartridges
!
© 25 889 0
© 25 888 1
6.4 Combustion Air Filter Service and Maintenance